{"id":16206,"date":"2022-07-16T19:36:35","date_gmt":"2022-07-16T19:36:35","guid":{"rendered":"https:\/\/blogs.ugto.mx\/rea\/?p=16206"},"modified":"2022-08-17T16:21:18","modified_gmt":"2022-08-17T16:21:18","slug":"clase-digital-2-propiedades-de-los-refrigerantes","status":"publish","type":"post","link":"https:\/\/blogs.ugto.mx\/rea\/clase-digital-2-propiedades-de-los-refrigerantes\/","title":{"rendered":"Clase digital 2. Propiedades de los refrigerantes"},"content":{"rendered":"\n\n\n<div class=\"wp-block-cover is-light\" style=\"min-height:284px;aspect-ratio:unset;\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-40 has-background-dim\"><\/span><img decoding=\"async\" class=\"wp-block-cover__image-background wp-image-17872\" alt=\"\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/giorgio-trovato-jJDgevLOoxM-unsplash.jpg\" style=\"object-position:46% 84%\" data-object-fit=\"cover\" data-object-position=\"46% 84%\" \/><noscript><img loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"1280\" class=\"wp-block-cover__image-background wp-image-17872\" alt=\"\" src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/giorgio-trovato-jJDgevLOoxM-unsplash.jpg\" style=\"object-position:46% 84%\" data-object-fit=\"cover\" data-object-position=\"46% 84%\" srcset=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/giorgio-trovato-jJDgevLOoxM-unsplash.jpg 1920w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/giorgio-trovato-jJDgevLOoxM-unsplash-300x200.jpg 300w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/giorgio-trovato-jJDgevLOoxM-unsplash-1024x683.jpg 1024w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/giorgio-trovato-jJDgevLOoxM-unsplash-768x512.jpg 768w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/giorgio-trovato-jJDgevLOoxM-unsplash-1536x1024.jpg 1536w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/giorgio-trovato-jJDgevLOoxM-unsplash-272x182.jpg 272w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><\/noscript><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<p class=\"has-text-align-center has-base-3-color has-text-color has-large-font-size wp-block-paragraph\">Propiedades de los refrigerantes<\/p>\n<\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"introduccion\">Introducci\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u00a1Hola amable estudiante!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Me siento muy feliz de encontrarte en esta segunda sesi\u00f3n del curso Ingenier\u00eda del Fr\u00edo, ya ver\u00e1s que lo que aprendas de ella ser\u00e1 muy ben\u00e9fico para tu formaci\u00f3n acad\u00e9mica, es por ello que te invito a conocerla.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En esta clase aprender\u00e1s diferentes cosas relacionadas a los refrigerantes. A manera de introducci\u00f3n, debes saber que el fluido que transporta el calor en un ciclo de refrigeraci\u00f3n se conoce como refrigerante. En ocasiones, este recibe un nombre considerado como hom\u00f3nimo el cual es fluido frigor\u00edgeno, por lo cual, en la literatura puedes encontrarte este concepto definido de ambas formas.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Es importante que no se confunda el t\u00e9rmino refrigerante con enfriador, ya que el primero puede ser utilizado a temperaturas por debajo de cero grados Celcius, mientras que el segundo solamente se utiliza para temperaturas por encima del punto de congelaci\u00f3n del agua.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para el tema en cuesti\u00f3n, te comento que revisaremos en esta sesi\u00f3n los siguientes puntos:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Historia de los refrigerantes.<\/li><li>Propiedades de los refrigerantes.<\/li><li>Nomenclatura de los refrigerantes.<\/li><li>Aspecto Ambiental.<\/li><li>Tendencias de los refrigerantes a nivel mundial.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">En los temas mencionados, aprender\u00e1s c\u00f3mo reconocer los refrigerantes y el impacto ambiental que \u00e9stos generan al ser empleados en los sistemas de refrigeraci\u00f3n por compresi\u00f3n de vapor. Tambi\u00e9n conocer\u00e1s los tipos de refrigerantes que existen y c\u00f3mo se presentan las tendencias a futuro en materia del uso de estas sustancias.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sin m\u00e1s pre\u00e1mbulo, te invito a que revises el material proporcionado para que puedas conocer m\u00e1s sobre este interesante tema que son los refrigerantes. Disfruta el contenido y recuerda que estoy a tu disposici\u00f3n para cualquier duda, comentario o pregunta sobre el tema de esta segunda sesi\u00f3n.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00a1Prosigamos!<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"desarrollo-del-tema\">Desarrollo del tema <\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Historia de los refrigerantes<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un refrigerante es una sustancia que tiene la capacidad de transmitir calor. Absorbe energ\u00eda t\u00e9rmica a bajas temperaturas y presiones y sede esta energ\u00eda a altas temperaturas y presiones. En sentido figurado, los refrigerantes pueden ser considerados como la sangre que trasiega sobre la tuber\u00eda de todo el sistema de refrigeraci\u00f3n por compresi\u00f3n de vapor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Los refrigerantes han venido evolucionando desde su creaci\u00f3n. Se tiene conocimiento que los primeros refrigerantes eran soluciones de agua con sal cuya temperatura era inferior a la del hielo, posteriormente se descubri\u00f3 que el fr\u00edo pod\u00eda conseguirse mediante una disminuci\u00f3n de presi\u00f3n de vapor en ciertas sustancias, las cuales tomaron el nombre de refrigerantes [1]. En aras de conseguir refrigeraci\u00f3n a placer, el ser humano empez\u00f3 a inventar m\u00e1quinas que consiguieran el objetivo de generar fr\u00edo bajando la presi\u00f3n de vapor de los refrigerantes.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En el siglo XVIII, Jacob Perkins construy\u00f3 la primera m\u00e1quina capaz de generar fr\u00edo por compresi\u00f3n de vapor utilizando \u00e9ter como refrigerante. Desde luego, este tipo de refrigerantes no eran nada amigables con el ser humano dado la toxicidad que presenta esta sustancia, por lo que se continu\u00f3 con la b\u00fasqueda de opciones que pudieran ser el reemplazo de esta sustancia.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En el mismo siglo, se utiliz\u00f3 una mezcla de agua y \u00e1cido sulf\u00farico para generar fr\u00edo, la cual consigui\u00f3 el objetivo, pero segu\u00eda utilizando sustancias t\u00f3xicas. En 1869, Ferdinand Carr\u00e9 construy\u00f3 una m\u00e1quina que utilizaba amoniaco y agua y los resultados fueron satisfactorios [2], tanto que hoy en d\u00eda el amoniaco sigue utiliz\u00e1ndose a nivel industrial para la generaci\u00f3n de fr\u00edo. No obstante, se necesitaban otros refrigerantes que pudieran ser utilizados en aplicaciones dom\u00e9sticas, comerciales y de climatizaci\u00f3n automotriz, por lo que la b\u00fasqueda continu\u00f3.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En el siglo XIX, intentos por conseguir refrigeraci\u00f3n con sustancias inocuas al ser humano fueron realizados por muchos investigadores siendo el di\u00f3xido de carbono uno de los que se perfilaba como una alternativa firme para ser la soluci\u00f3n, sin embargo, este refrigerante ten\u00eda algunas caracter\u00edsticas que jugaban en su contra, entre ellas estaban sus altas presiones de trabajo y su bajo desempe\u00f1o energ\u00e9tico. Es as\u00ed que,&nbsp; a inicios del siglo XX (1930) Thomas Midgley anunci\u00f3 el nacimiento de los refrigerantes halogenados, los cuales fueron propuestos como los que reemplazar\u00edan al di\u00f3xido de carbono y todos aquellos refrigerantes que pudieran comprometer el desempe\u00f1o energ\u00e9tico, toxicidad y flamabilidad [3]. Era el nacimiento de una segunda generaci\u00f3n, la de los refrigerantes con alto desempe\u00f1o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Los refrigerantes halogenados se utilizaron sin ning\u00fan inconveniente hasta finales de 1960, cuando cient\u00edficos a nivel mundial descubrieron la formaci\u00f3n de un agujero en la capa de ozono, producto justamente del uso desmedido de sustancias que conten\u00edan cloro en su mol\u00e9cula principal, los halogenados. En 1974, Sherwood Rowland fue el primero que sospech\u00f3 sobre este problema y en 1985, Mario Molina confirm\u00f3 las sospechas que hac\u00eda 11 a\u00f1os ya se ten\u00edan [4]. A partir de aqu\u00ed, los refrigerantes halogenados estuvieron en la mira a nivel internacional y, fue hasta 1987, cuando con base al protocolo de Montreal se propuso su eliminaci\u00f3n [5].<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nace entonces la tercera generaci\u00f3n de refrigerantes donde lo que se ten\u00eda que evadir era precisamente refrigerantes con contenido de cloro en su mol\u00e9cula principal, toda vez que se descubri\u00f3 que la mol\u00e9cula de cloro, al unirse con el ozono formaba \u00f3xido de cloro + ox\u00edgeno en la estratosfera, compuesto que no ayuda nada con la eliminaci\u00f3n de rayos UV que tanto da\u00f1o producen a los seres vivos [6].<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para 1997 se empez\u00f3 a presentar un fen\u00f3meno a nivel mundial, el cual era el cambio clim\u00e1tico producido por el calentamiento excesivo de la superficie terrestre, producto del uso de gases de efecto invernadero, como lo son los refrigerantes de tercera generaci\u00f3n. Para regular este problema, se emite el Protocolo de Kioto [7] en el a\u00f1o mencionado, el cual es un instrumento que permite la regulaci\u00f3n del uso desmedido de refrigerantes con alto potencial de calentamiento global. A partir de aqu\u00ed, inicia la cuarta generaci\u00f3n de refrigerantes, la cual tiene como objetivo principal, la eliminaci\u00f3n paulatina de refrigerantes que da\u00f1en la capa de ozono y que tengan un potencial de calentamiento global de tres d\u00edgitos.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para darle mayor fuerza a estas iniciativas, en 2016 se emite la enmienda de Kigali [8], la cual fortalece al Protocolo de Kioto y es la que actualmente est\u00e1 en vigor a nivel internacional en materia de regulaci\u00f3n de gases de efecto invernadero. La Diagrama 1 muestra una infograf\u00eda de la evoluci\u00f3n hist\u00f3rica de los refrigerantes.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-13.36.46-1024x672.png\" alt=\"\" class=\"wp-image-17863\" \/><noscript><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"672\" src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-13.36.46-1024x672.png\" alt=\"\" class=\"wp-image-17863\" srcset=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-13.36.46-1024x672.png 1024w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-13.36.46-300x197.png 300w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-13.36.46-768x504.png 768w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-13.36.46.png 1038w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/noscript><figcaption><strong>Diagrama 1. <\/strong>Generaciones de refrigerantes.<\/figcaption><\/figure>\n<\/div>\n\n\n<h4 class=\"wp-block-heading\">Propiedades de los refrigerantes<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Las propiedades son las caracter\u00edsticas t\u00edpicas de cualquier sustancia. A continuaci\u00f3n se mencionan algunas de las propiedades m\u00e1s importantes de los refrigerantes:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Punto de burbuja: Es la temperatura a la cual un l\u00edquido saturado comienza a hervir.<\/li><li>Punto de roc\u00edo: <ul><li>Es la temperatura a la cual un l\u00edquido saturado evapora su \u00faltima gota, o cuando aparece la primer gota de l\u00edquido en un vapor saturado.<\/li><li>En los compuestos puros el punto de roc\u00edo y el punto de burbuja ocurren a la misma temperatura,<\/li><li>En el caso de las mezclas, el punto de burbuja ocurre a una temperatura menor que el punto de roc\u00edo a una presi\u00f3n constante.<\/li><\/ul><\/li><\/ul>\n\n\n\n<ul class=\"wp-block-list\"><li>Deslizamiento de temperatura (Glide): Es la diferencia de temperatura entre el punto de roc\u00edo y el punto de burbuja.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Cabe mencionar que, a mayor valor de deslizamiento de temperatura mayor es la probabilidad de descompensaci\u00f3n de un refrigerante a la hora de ocurrir una fuga. Entre m\u00e1s bajo es el valor del deslizamiento de temperatura, la mezcla tiene un comportamiento m\u00e1s parecido a un compuesto puro. En la Figura 2, se muestran las propiedades descritas anteriormente en un diagrama Temperatura vs Calor. Diagrama 2 muestra un comparativo para el R134a y el R409A.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-13.42.43.png\" alt=\"\" class=\"wp-image-17864\" \/><noscript><img loading=\"lazy\" decoding=\"async\" width=\"817\" height=\"595\" src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-13.42.43.png\" alt=\"\" class=\"wp-image-17864\" srcset=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-13.42.43.png 817w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-13.42.43-300x218.png 300w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-13.42.43-768x559.png 768w\" sizes=\"auto, (max-width: 817px) 100vw, 817px\" \/><\/noscript><figcaption><strong>Diagrama 2.<\/strong> Temperatura vs Calor para refrigerantes R134a y R409A.<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Los refrigerantes se pueden clasificar de acuerdo a diferentes tipos, por ejemplo, una clasificaci\u00f3n muy conocida se muestra en la Diagrama 3.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-14.01.18.png\" alt=\"\" class=\"wp-image-17866\" width=\"842\" height=\"285\" \/><noscript><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-14.01.18.png\" alt=\"\" class=\"wp-image-17866\" width=\"842\" height=\"285\" srcset=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-14.01.18.png 1010w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-14.01.18-300x102.png 300w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-14.01.18-768x260.png 768w\" sizes=\"auto, (max-width: 842px) 100vw, 842px\" \/><\/noscript><figcaption><strong>Diagrama 3.<\/strong> Clasificaci\u00f3n t\u00edpica de los refrigerantes.<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">De la Diagrama 3, puede mencionarse que los refrigerantes naturales no inflamables son aquellos que no tienen afinidad a arder f\u00e1cilmente. Los refrigerantes que caen dentro de este rubro son: Di\u00f3xido de Carbono, Amoniaco, Agua y Aire. Por otro lado, en el tema de los refrigerantes naturales inflamables, es decir aquellos que encienden a gran velocidad, los hidrocarburos son los que ocupan este puesto. Los refrigerantes que est\u00e1n en esta clasificaci\u00f3n son el Propano, Isobutano y el Propileno [9].&nbsp;&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Una de las caracter\u00edsticas que tienen los refrigerantes naturales es que todos ellos poseen valores de potencial de destrucci\u00f3n del ozono (ODP, por sus siglas en ingl\u00e9s) nulo, y por lo general presentan valores potenciales de calentamiento atmosf\u00e9rico (PCA), bajos, incluso cerca de la unidad. Sin embargo, no son tan utilizados de manera general porque presentan peculiaridades que los convierten en opciones no tan pr\u00e1cticas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para la clasificaci\u00f3n de los refrigerantes sint\u00e9ticos, se encuentran aquellos que son puros y las mezclas. Dentro de las mezclas se conocen las zeotr\u00f3picas y las azeotr\u00f3picas.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>M<strong>ezclas zeotr\u00f3picas<\/strong>: Se le llama mezcla zeotr\u00f3pica a la mezcla de dos o m\u00e1s refrigerantes puros con diferentes volatilidades.<\/li><li><strong>Mezclas azeotr\u00f3picas: <\/strong>Las mezclas azeotr\u00f3picas ocurren cuando las interacciones fisicoqu\u00edmicas entre los componentes de la mezcla a una concentraci\u00f3n espec\u00edfica son tan fuertes, esto porque las volatilidades de los componentes de la mezcla se igualan en un punto espec\u00edfico.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Las mezclas azeotr\u00f3picas tienen la ventaja de que, al comportarse como un compuesto puro,&nbsp;se pueden cargar al sistema en cualquier fase, mientras que&nbsp;las mezclas zeotr\u00f3picas deben cargarse siempre en la fase l\u00edquida. Diagrama 4 muestra una representaci\u00f3n gr\u00e1fica de lo que sucede con las mezclas de refrigerantes.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-14.10.30.png\" alt=\"\" class=\"wp-image-17870\" \/><noscript><img loading=\"lazy\" decoding=\"async\" width=\"670\" height=\"428\" src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-14.10.30.png\" alt=\"\" class=\"wp-image-17870\" srcset=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-14.10.30.png 670w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-14.10.30-300x192.png 300w\" sizes=\"auto, (max-width: 670px) 100vw, 670px\" \/><\/noscript><figcaption><strong>Diagrama 4.<\/strong> Esquema de la diferencia entre una mezcla zeotr\u00f3pica y una no azeotr\u00f3pica en refrigerantes.<\/figcaption><\/figure>\n<\/div>\n\n\n<h4 class=\"wp-block-heading\">Nomenclatura de los refrigerantes<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">La forma de nombrar a un refrigerante est\u00e1 establecida mediante el est\u00e1ndar 32 de la sociedad americana de ingenieros en aire acondicionado y refrigeraci\u00f3n (ASHRAE, por sus siglas en ingl\u00e9s). Este est\u00e1ndar resume la manera de nombrar a los refrigerantes en la Tabla 1.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tabla 1. Algunas caracter\u00edsticas de clasificaci\u00f3n del Standard 34.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-14.17.15.png\" alt=\"\" class=\"wp-image-17871\" \/><noscript><img loading=\"lazy\" decoding=\"async\" width=\"773\" height=\"333\" src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-14.17.15.png\" alt=\"\" class=\"wp-image-17871\" srcset=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-14.17.15.png 773w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-14.17.15-300x129.png 300w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/08\/Captura-de-Pantalla-2022-08-15-a-las-14.17.15-768x331.png 768w\" sizes=\"auto, (max-width: 773px) 100vw, 773px\" \/><\/noscript><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">De acuerdo a esta Tabla 1, los refrigerantes conocidos como inorg\u00e1nicos, pueden nombrarse con base al est\u00e1ndar 32 de la ASHRAE, considerando adem\u00e1s el peso molecular de la sustancia, por ejemplo, si se quiere nombrar al di\u00f3xido de carbono de acuerdo a este est\u00e1ndar, se debe considerar en primera instancia que se trata de una sustancia inorg\u00e1nica, por lo que el primer d\u00edgito deber\u00e1 ser el 7, a continuaci\u00f3n se debe considerar el peso molecular del refrigerante, el di\u00f3xido de carbono tiene un peso molecular de 44 g\/mol, por lo que el nombre para esta sustancia como refrigerante ser\u00e1 R744. De la misma manera se har\u00eda para el agua, el amon\u00edaco, el aire, etc.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Aspecto ambiental<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">En relaci\u00f3n a lo que tiene que ver con el tema ambiental, los refrigerantes pueden ser evaluados mediantes diferentes par\u00e1metros. Los m\u00e1s conocidos son el ODP (Ozone Depletion Potential) y el GWP (Global Warming Potential). El segundo se puede encontrar tambi\u00e9n como PCA (Potencial de Calentamiento Atmosf\u00e9rico) o PCG (Potencial de Calentamiento Global), mientras que el primero tambi\u00e9n se encuentra como PAO (Potencial de Agotamiento del Ozono). El ODP es una medida del potencial que posee un refrigerante para destruir el ozono en la estrat\u00f3sfera, mientras que el GWP cuantifica la capacidad de contribuci\u00f3n al calentamiento global de la superficie terrestre. Estos par\u00e1metros vienen relacionados con el tipo de refrigerante, as\u00ed los refrigerantes naturales, como ya se mencion\u00f3 en el tema anterior, presentan valores de ambos par\u00e1metros nulos para el ODP y muy bajos para el GWP. Como era de esperarse, los valores altos y significativos de estos par\u00e1metros se alcanzan en los refrigerantes sint\u00e9ticos. Aunado a estos par\u00e1metros, existen un par de m\u00e9todos para cuantificar el da\u00f1o de un refrigerante en funci\u00f3n de ciertos par\u00e1metros. Estos m\u00e9todos son el TEWI (Total Equivalent Warming Impact) y el LCCP (Life Cycle Climate Performance).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El TEWI es la medida del impacto total equivalente sobre el calentamiento atmosf\u00e9rico [10]. Este m\u00e9todo resulta de la sumatoria del impacto directo que un refrigerante tiene al ambiente con el impacto indirecto del mismo refrigerante. En esta metodolog\u00eda, es imprescindible que no existan fugas en los sistemas de refrigeraci\u00f3n, ya que en presencia de fugas, el calentamiento global directo se hace presente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El LCCP es un m\u00e9todo de evaluaci\u00f3n para sistemas de refrigeraci\u00f3n, climatizaci\u00f3n, ventilaci\u00f3n y calentamiento el cual eval\u00faa el impacto al calentamiento global de la vida completa de un refrigerante desde que se produce hasta que es liberado a la atm\u00f3sfera [11].<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Tendencias de los refrigerantes a nivel mundial<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Los refrigerantes hoy en d\u00eda est\u00e1n direccionados a ser utilizados con base a su PCA. De acuerdo a la normativa Europea No. 517\/2014, la tendencia hacia el uso de refrigerantes en el futuro pr\u00f3ximo debe ser con base al nivel de PCA que \u00e9stos tengan [12]. Al tener cuantificado tanto el ODP como el PCA, la tendencia ser\u00e1 siempre a que los refrigerantes a utilizarse en equipos nuevos cumplan con caracter\u00edsticas de nulo ODP y un PCA que sea solo de tres d\u00edgitos. En aplicaciones de climatizaci\u00f3n automotriz, se ha fijado incluso un valor para que un refrigerante pueda ser utilizado, este valor es de PCA&lt;150.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Los refrigerantes que cumplen perfectamente con estas pol\u00edticas son los naturales, sin embargo, como es sabido, presentan problemas de seguridad, toxicidad e inflamabilidad. Por otro lado, los refrigerantes sint\u00e9ticos han ido aline\u00e1ndose a estas pol\u00edticas, por lo que existen actualmente un grupo de sustancias que est\u00e1n disponibles como opciones para su uso y que cumplen con las disposiciones gubernamentales a nivel internacional. Se trata de las Hidrofluorolefinas o HFOs, las cuales son un grupo de refrigerantes de cuarta generaci\u00f3n que intentan apoderarse del mercado de los refrigerantes debido a sus bajos niveles de PCA y a su nulo ODP. Aunado a estas sustancias, la presencia de mezclas que continuamente son creadas, tambi\u00e9n resultan una opci\u00f3n para el mercado de la refrigeraci\u00f3n por compresi\u00f3n de vapor, ya que resultan cumplir con las pol\u00edticas y adem\u00e1s se alcanzan niveles competitivos de desempe\u00f1o con algunas de ellas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En apoyo de tu aprendizaje te invito a ver los siguientes videos:<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Tipos de gases refrigerantes usados en la actualidad\" width=\"1200\" height=\"675\" src=\"https:\/\/www.youtube.com\/embed\/CsUaLuuy9P0?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"GWPs, Emission Factors, &amp; Carbon vs. CO2\" width=\"1200\" height=\"675\" src=\"https:\/\/www.youtube.com\/embed\/niotf0oHvQY?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\">Conclusi\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">En conclusi\u00f3n, el uso de refrigerantes es una actividad que se realiza en la refrigeraci\u00f3n por compresi\u00f3n de vapor, ya que estos fluidos son los que aportan la absorci\u00f3n de calor y con ello, la generaci\u00f3n de fr\u00edo. Existen diversas clasificaciones de los refrigerantes, una de las m\u00e1s t\u00edpicas es la de naturales y sint\u00e9ticos.<br>La evoluci\u00f3n de los refrigerantes puede resumirse en cuatro generaciones, siendo la cuarta la que actualmente se est\u00e1 viviendo.<br>Los refrigerantes son nombrados con base al est\u00e1ndar internacional 32 de la ASHRAE. De acuerdo a esto, los frigor\u00edgenos son clasificados hasta en siete categor\u00edas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El impacto ambiental que generan los refrigerantes es tal que se han tenido que emitir dos protocolos importantes en materia de regulaci\u00f3n de refrigerantes: El Protocolo de Montreal, relativo a sustancias que destruyen el ozono estratosf\u00e9rico y el Protocolo de Kioto, que relaciona y regula los gases de efecto invernadero en el mundo. Ambos protocolos est\u00e1n directamente relacionados con los refrigerantes debido a su potencial de destrucci\u00f3n del ozono y de su potencial de calentamiento global.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La tendencia en el uso de refrigerantes es clara y es hacia aquellos que demuestren tener un ODP nulo y un bajo GWP. Adem\u00e1s de que se eval\u00faan otros factores como el desempe\u00f1o energ\u00e9tico, el costo y la seguridad, los primeros dos factores resultan preponderantes para emplear refrigerantes, sobre todo en instalaciones o sistemas de refrigeraci\u00f3n o climatizaci\u00f3n nuevos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Lo revisado en esta sesi\u00f3n, da un panorama para conocer un poco m\u00e1s la importancia de los refrigerantes, y el porqu\u00e9 deben considerarse como punto clave en los sistemas de refrigeraci\u00f3n. Si\u00e9ntete con toda confianza de cuestionar detalles que no te hayan quedado claros y los resolveremos en breve.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Has llegado al final de la segunda clase. \u00a1Vas muy bien, te felicito! Recuerda hacer y mandar la tarea correspondiente a esta lecci\u00f3n. Sigue avanzando como hasta ahora, te encuentro en la siguiente clase, hasta luego.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"fuentes-de-informacion\">Fuentes de informaci\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"http:\/\/www.indubel.com.ar\/pdf\/gases\/refrigerantes.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">REFRIGERANTES<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.climasmonterrey.com\/historia-de-los-refrigerantes\">\u00bfCu\u00e1l es la historia de los Refrigerantes?<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/andira.org.mx\/admin\/2018\/08\/13\/historia-de-los-refrigerantes\/\" target=\"_blank\" rel=\"noreferrer noopener\">Historia de los refrigerantes \u2013 Andira<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.atmosfera.unam.mx\/historica-recuperacion-de-la-capa-de-ozono\/\" target=\"_blank\" rel=\"noreferrer noopener\">Hist\u00f3rica recuperaci\u00f3n de la capa de ozono<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/observatoriop10.cepal.org\/es\/tratados\/protocolo-montreal-relativo-sustancias-que-agotan-la-capa-ozono#:~:text=El%20Protocolo%20de%20Montreal%20relativo%20a%20las%20Sustancias%20Agotadoras%20de,ocasiones%20y%20modificado%20en%20cuatro\" target=\"_blank\" rel=\"noreferrer noopener\">El Protocolo De Montreal Relativo a Las Sustancias Que Agotan La Capa De Ozono | Observatorio del Principio 10<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"http:\/\/www.ideam.gov.co\/web\/tiempo-y-clima\/formacion-y-destruccion-del-ozono-estratosferico\" target=\"_blank\" rel=\"noreferrer noopener\">FORMACI\u00d3N Y DESTRUCCI\u00d3N DEL OZONO ESTRATOSF\u00c9RICO &#8211; IDEAM<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.gob.mx\/semarnat\/articulos\/protocolo-de-kioto-sobre-cambio-climatico\" target=\"_blank\" rel=\"noreferrer noopener\">Protocolo de Kioto sobre cambio clim\u00e1tico | Secretar\u00eda de Medio Ambiente y Recursos Naturales | Gobierno | gob.mx<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.unep.org\/es\/noticias-y-reportajes\/comunicado-de-prensa\/entra-en-vigor-la-enmienda-kigali-un-poderoso-aliado-en\" target=\"_blank\" rel=\"noreferrer noopener\">Entra en vigor la Enmienda Kigali, un poderoso aliado en la lucha contra el cambio clim\u00e1tico<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.danfoss.com\/es-mx\/about-danfoss\/our-businesses\/cooling\/refrigerants-and-energy-efficiency\/refrigerants-for-lowering-the-gwp\/hydrocarbons\/#:~:text=Los%20hidrocarburos%20forman%20parte%20del,subproductos%20de%20la%20industria%20petroqu%C3%ADmica\" target=\"_blank\" rel=\"noreferrer noopener\">Hidrocarburos | Refrigerantes naturales para reducir el GWP | Danfoss<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/torrington.com.ar\/blog\/buenaspracticas\/que-significa-tewi\/\" target=\"_blank\" rel=\"noreferrer noopener\">\u00bfQu\u00e9 significa TEWI? | Torrington Refrigerantes<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Troch, S., Lee, H., Hwang, Y., &amp; Radermacher, R. (2016). <em>Harmonization of Life Cycle Climate Performance (LCCP) Methodology: International Refrigeration and Air Conditioning Conference. <\/em>paper 1724.&nbsp; Extra\u00eddo de: <a href=\"https:\/\/docs.lib.purdue.edu\/iracc\/1724\/\" target=\"_blank\" rel=\"noreferrer noopener\">\u00abHarmonization of Life Cycle Climate Performance (LCCP) Methodology\u00bb by Sarah Troch, Hoseong Lee et al.<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Extra\u00eddo de: Reglamento UE No. 517\/2014 del Parlamento Europeo y del Consejo, 2016, <a href=\"https:\/\/www.boe.es\/doue\/2014\/150\/L00195-00230.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Reglamento (UE) no 517\/2014 del Parlamento Europeo y del Consejo, de 16 de abril de 2014, sobre los gases fluorados de efecto in<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Introducci\u00f3n \u00a1Hola amable estudiante! Me siento muy feliz de encontrarte en esta segunda sesi\u00f3n del curso Ingenier\u00eda del Fr\u00edo, ya ver\u00e1s que lo que aprendas de ella ser\u00e1 muy ben\u00e9fico para tu formaci\u00f3n acad\u00e9mica, es por ello que te invito a conocerla. En esta clase aprender\u00e1s diferentes cosas relacionadas a los refrigerantes. A manera de &#8230; <a title=\"Clase digital 2. Propiedades de los refrigerantes\" class=\"read-more\" href=\"https:\/\/blogs.ugto.mx\/rea\/clase-digital-2-propiedades-de-los-refrigerantes\/\" aria-label=\"Leer m\u00e1s sobre Clase digital 2. Propiedades de los refrigerantes\">Leer m\u00e1s<\/a><\/p>\n","protected":false},"author":142,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_crdt_document":"","episode_type":"","audio_file":"","podmotor_file_id":"","podmotor_episode_id":"","cover_image":"","cover_image_id":"","duration":"","filesize":"","filesize_raw":"","date_recorded":"","explicit":"","block":"","itunes_episode_number":"","itunes_title":"","itunes_season_number":"","itunes_episode_type":"","footnotes":""},"categories":[180,477,478],"tags":[41,479,103],"class_list":["post-16206","post","type-post","status-publish","format-standard","hentry","category-cideap","category-licenciatura-en-ingenieria-en-alimentos","category-uda-ingenieria-del-frio","tag-clase-digital","tag-iili03012","tag-vicente-perez-garcia"],"acf":[],"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/posts\/16206","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/users\/142"}],"replies":[{"embeddable":true,"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/comments?post=16206"}],"version-history":[{"count":7,"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/posts\/16206\/revisions"}],"predecessor-version":[{"id":18082,"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/posts\/16206\/revisions\/18082"}],"wp:attachment":[{"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/media?parent=16206"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/categories?post=16206"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/tags?post=16206"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}