{"id":8143,"date":"2022-02-24T19:33:52","date_gmt":"2022-02-24T19:33:52","guid":{"rendered":"https:\/\/blogs.ugto.mx\/rea\/?p=8143"},"modified":"2022-03-10T20:12:43","modified_gmt":"2022-03-10T20:12:43","slug":"clase-digital-11-modificaciones-a-redes-de-recuperacion-de-calor-para-reducir-del-numero-de-equipos","status":"publish","type":"post","link":"https:\/\/blogs.ugto.mx\/rea\/clase-digital-11-modificaciones-a-redes-de-recuperacion-de-calor-para-reducir-del-numero-de-equipos\/","title":{"rendered":"Clase digital 11. Modificaciones a redes de recuperaci\u00f3n de calor para reducir del n\u00famero de equipos"},"content":{"rendered":"\n<div class=\"wp-block-cover is-light\" style=\"min-height:284px;aspect-ratio:unset;\"><span aria-hidden=\"true\" class=\"has-background-dim-40 wp-block-cover__gradient-background has-background-dim\"><\/span><img decoding=\"async\" class=\"wp-block-cover__image-background wp-image-8144\" alt=\"person using black laptop computer\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/2mbtxgq4pfs.jpg\" style=\"object-position:64% 23%\" data-object-fit=\"cover\" data-object-position=\"64% 23%\" \/><noscript><img loading=\"lazy\" decoding=\"async\" width=\"1600\" height=\"1067\" class=\"wp-block-cover__image-background wp-image-8144\" alt=\"person using black laptop computer\" src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/2mbtxgq4pfs.jpg\" style=\"object-position:64% 23%\" data-object-fit=\"cover\" data-object-position=\"64% 23%\" srcset=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/2mbtxgq4pfs.jpg 1600w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/2mbtxgq4pfs-300x200.jpg 300w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/2mbtxgq4pfs-1024x683.jpg 1024w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/2mbtxgq4pfs-768x512.jpg 768w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/2mbtxgq4pfs-1536x1024.jpg 1536w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/2mbtxgq4pfs-272x182.jpg 272w\" sizes=\"auto, (max-width: 1600px) 100vw, 1600px\" \/><\/noscript><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<p class=\"has-text-align-center has-base-3-color has-text-color has-large-font-size wp-block-paragraph\">Modificaciones a redes de recuperaci\u00f3n de calor para reducir del n\u00famero de equipos<\/p>\n<\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"introduccion\">Introducci\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u00a1Hola!&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Espero que este d\u00eda se complemente con muchas satisfacciones para ti y goces de una salud envidiable. Te doy una calurosa bienvenida a la d\u00e9cimo primera clase del curso Integraci\u00f3n de Procesos.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El tema que abordaremos en esta sesi\u00f3n consiste en c\u00f3mo analizar, en la etapa de dise\u00f1o, las opciones para reducir el n\u00famero de equipos de intercambio de calor en una red. Este tipo de an\u00e1lisis encuentra aplicaciones en casos en los cuales el costo de los intercambiadores de calor es muy alto, como en el caso de titanio, lo que justificar\u00eda buscar reducir su n\u00famero.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Existen dos tipos fundamentales de subestructuras dentro de una red que se pueden explorar para llevar a cabo un proceso de reducci\u00f3n de unidades, se trata de los ciclos y de las rutas t\u00e9rmicas. Un ciclo es un subsistema, dentro de una red de recuperaci\u00f3n de calor integrado por enlaces t\u00e9rmicos (intercambiadores de calor) y corrientes de proceso. Su caracter\u00edstica principal es que permite transferir cargas t\u00e9rmicas entre sus intercambiadores. A trav\u00e9s de la eliminaci\u00f3n de ciclos se puede reducir el n\u00famero de intercambiadores de calor de un sistema.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Una ruta t\u00e9rmica es un subsistema dentro de una red de recuperaci\u00f3n de calor, que vincula un calentador y un enfriador a trav\u00e9s de enlaces t\u00e9rmicos (intercambiadores de calor) y corrientes de proceso. Una ruta t\u00e9rmica se puede utilizar de dos maneras:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Para restablecer el \u0394T<sub>min<\/sub> cuando se eliminan intercambiadores de calor a trav\u00e9s del incremento del consumo de energ\u00eda.<\/li><li>Para reducir el consumo de energ\u00eda del proceso en casos de readecuaci\u00f3n (retrofit).<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">El objetivo de esta clase es que desarrolles la habilidad para identificar ciclos y rutas t\u00e9rmicas dentro de una red de recuperaci\u00f3n de calor y las puedas emplear como un recurso para que, en situaciones donde sea factible econ\u00f3micamente reducir el n\u00famero de unidades, cuentes con los elementos para la toma de decisiones.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sin otro en particular, damos inicio a la clase.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"desarrollo-del-tema\">Desarrollo del tema<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Cuando se dise\u00f1a una red de recuperaci\u00f3n de calor de acuerdo con los principios del m\u00e9todo Pinch, las zonas arriba y abajo del Pinch se dise\u00f1an de manera independiente. Con frecuencia, cuando los dise\u00f1os se unen, se crean ciclos. Como se vio en clases anteriores, la expresi\u00f3n para determinar el n\u00famero m\u00ednimo de equipos de transferencia de calor tiene un t\u00e9rmino que est\u00e1 relacionado con el n\u00famero de ciclos. De acuerdo con la ecuaci\u00f3n (1), el n\u00famero de ciclos incrementa el n\u00famero de equipos de transferencia de calor.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.08.22.png\" alt=\"\" class=\"wp-image-9005\" \/><noscript><img loading=\"lazy\" decoding=\"async\" width=\"468\" height=\"70\" src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.08.22.png\" alt=\"\" class=\"wp-image-9005\" srcset=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.08.22.png 468w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.08.22-300x45.png 300w\" sizes=\"auto, (max-width: 468px) 100vw, 468px\" \/><\/noscript><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Las rutas t\u00e9rmicas, por otro lado, son subsistemas que unen un servicio de calentamiento con uno de enfriamiento a trav\u00e9s de corrientes de proceso e intercambiadores de calor. Tanto los ciclos como las rutas t\u00e9rmicas pueden transferir carga t\u00e9rmica. La diferencia es que un ciclo transfiere carga t\u00e9rmica de la que se tiene dentro del proceso a otro intercambiador, mientras que una ruta t\u00e9rmica transmite carga t\u00e9rmica externa. Esta caracter\u00edstica la convierte en una subred que puede explotarse en proyectos de reducci\u00f3n del consumo de energ\u00eda como se ver\u00e1 en otra clase. Por lo pronto, en el contexto de eliminaci\u00f3n de equipos, la ruta se utiliza para restablecer el \u0394T<sub>min<\/sub> del proceso.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En la Figura 1, se observa una red de recuperaci\u00f3n de calor donde se resalta un ciclo (l\u00ednea en rojo) y una ruta t\u00e9rmica (l\u00ednea en verde). Como se puede observar, el ciclo ocurre entre los intercambiadores E4 y E1. Se dice que estos intercambiadores son activos porque pueden transferir carga t\u00e9rmica. El intercambiador de calor E3 no es un equipo activo pues no cambia su carga t\u00e9rmica, sin embargo, participa de manera pasiva pues los cambios de carga t\u00e9rmica afectan las temperaturas a su alrededor y por lo tanto su desempe\u00f1o.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.08.55.png\" alt=\"\" class=\"wp-image-9007\" \/><noscript><img loading=\"lazy\" decoding=\"async\" width=\"980\" height=\"397\" src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.08.55.png\" alt=\"\" class=\"wp-image-9007\" srcset=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.08.55.png 980w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.08.55-300x122.png 300w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.08.55-768x311.png 768w\" sizes=\"auto, (max-width: 980px) 100vw, 980px\" \/><\/noscript><figcaption>Figura 1. Representaci\u00f3n gr\u00e1fica de la existencia de ciclos y rutas t\u00e9rmicas en una red de recuperaci\u00f3n de calor.<\/figcaption><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Eliminaci\u00f3n de ciclos<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">El proceso para la eliminaci\u00f3n de ciclos inicia identificando preferentemente la transferencia de la menor de las cargas dentro del ciclo. En el caso de la Figura 1, se trata del intercambiador E4. En principio para poder eliminar este intercambiador, se debe transferir toda su carga t\u00e9rmica al equipo E1. Este movimiento se ilustra en la Figura 2.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.09.30.png\" alt=\"\" class=\"wp-image-9008\" \/><noscript><img loading=\"lazy\" decoding=\"async\" width=\"1006\" height=\"407\" src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.09.30.png\" alt=\"\" class=\"wp-image-9008\" srcset=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.09.30.png 1006w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.09.30-300x121.png 300w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.09.30-768x311.png 768w\" sizes=\"auto, (max-width: 1006px) 100vw, 1006px\" \/><\/noscript><figcaption>Figura 2. <em>Transferencia de carga t\u00e9rmica del intercambiador E4 al E1.<\/em><\/figcaption><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">El movimiento de carga t\u00e9rmica tiene dos consecuencias:&nbsp;<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Altera los balances de energ\u00eda de las corrientes involucradas.<\/li><li>Altera las temperaturas a la entrada y salida de los equipos modificando sus cargas t\u00e9rmicas.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ambos tipos de efecto se deben analizar. En esta clase nos concentraremos en la modificaci\u00f3n a los balances de energ\u00eda y c\u00f3mo restablecerlos. El segundo efecto se puede analizar utilizando los conceptos de propagaci\u00f3n de disturbios que se revisaron en clases anteriores.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Al desplazar la carga de 30 unidades al intercambiador E1, la temperatura de salida de la corriente 2H del intercambiador E1 pasa de ser 90\u00b0C a 70\u00b0C (Figura 3). Esto significa que el intercambiador E1 ahora tendr\u00e1 una diferencia de temperatura fr\u00eda en su lado de 5\u00b0C (70\u00b0- 65\u00b0C). Esta temperatura es muy peque\u00f1a y de no corregirse, crear\u00eda un efecto adverso en el equipo pues, al dise\u00f1arlo, se requerir\u00e1 un \u00e1rea de transferencia de calor mayor debido al peque\u00f1o gradiente de temperatura. La forma de restablecer esta temperatura es a trav\u00e9s del movimiento de carga t\u00e9rmica utilizando la ruta t\u00e9rmica. El objetivo es restablecer el \u0394T<sub>min<\/sub> del lado fr\u00edo de E1 a 10\u00b0C. Para ello se plantea el balance para encontrar cu\u00e1l debe ser la carga t\u00e9rmica de E1 para que la temperatura de salida de la corriente caliente sea 75\u00b0C. El c\u00e1lculo es el siguiente:<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">120-X = (1.5) (150\u00b0C-75\u00b0C)<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">X = 7.5<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Este resultado indica que es necesario incrementar la carga t\u00e9rmica del calentador H en 7.5 unidades (Figura 4). Al hacerlo, se debe reducir la carga de E1 en esa misma cantidad para mantener el balance de energ\u00eda en la corriente 1C. Por otro lado, al reducir la carga de la corriente 2H, la forma de mantener su balance de energ\u00eda es aumentando la carga del enfriador C en las mismas 7.5 unidades. La Figura 5 muestra el resultado final.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.10.03.png\" alt=\"\" class=\"wp-image-9009\" \/><noscript><img loading=\"lazy\" decoding=\"async\" width=\"922\" height=\"376\" src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.10.03.png\" alt=\"\" class=\"wp-image-9009\" srcset=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.10.03.png 922w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.10.03-300x122.png 300w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.10.03-768x313.png 768w\" sizes=\"auto, (max-width: 922px) 100vw, 922px\" \/><\/noscript><figcaption>Figura 3. <em>Ajuste de temperaturas despu\u00e9s de eliminar el intercambiador E4.<\/em><\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.10.37.png\" alt=\"\" class=\"wp-image-9010\" \/><noscript><img loading=\"lazy\" decoding=\"async\" width=\"844\" height=\"348\" src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.10.37.png\" alt=\"\" class=\"wp-image-9010\" srcset=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.10.37.png 844w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.10.37-300x124.png 300w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.10.37-768x317.png 768w\" sizes=\"auto, (max-width: 844px) 100vw, 844px\" \/><\/noscript><figcaption>Figura 4. <em>Balance de energ\u00eda para restablecer el \u0394Tmin del lado fr\u00edo del intercambiador E1.<\/em><\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.11.04.png\" alt=\"\" class=\"wp-image-9011\" \/><noscript><img loading=\"lazy\" decoding=\"async\" width=\"977\" height=\"409\" src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.11.04.png\" alt=\"\" class=\"wp-image-9011\" srcset=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.11.04.png 977w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.11.04-300x126.png 300w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.11.04-768x322.png 768w\" sizes=\"auto, (max-width: 977px) 100vw, 977px\" \/><\/noscript><figcaption>Figura 5. <em>Cargas t\u00e9rmicas finales.<\/em><\/figcaption><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Con esta estrategia se logra reducir una unidad, pero a cambio se tiene que incrementar el consumo de energ\u00eda. La carga t\u00e9rmica del calentador es 27.5 unidades y la del enfriador 67.5. Se debe notar que ambos equipos (H y C) incrementaron su carga t\u00e9rmica en la misma cantidad que se elimin\u00f3 del intercambiador E4. Alternativamente se puede establecer un an\u00e1lisis para determinar hasta qu\u00e9 punto es factible econ\u00f3micamente s\u00f3lo incrementar el \u00e1rea de los equipos cuyos gradientes se redujeron en lugar de incrementar el consumo de energ\u00eda.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Los ciclos pueden ser m\u00e1s complicados que el de la Figura 1. En ocasiones no s\u00f3lo incluyen m\u00e1s intercambiadores activos, sino que tambi\u00e9n incluyen calentadores y enfriadores. La Figura 6 muestra un ejemplo donde se destacan tres tipos diferentes de ciclos.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Ciclo 1 (l\u00ednea roja), integrado por: corriente 1H y 2C, e intercambiadores E1 y E4.<\/li><li>Ciclo 2 (l\u00ednea verde), integrado por: corrientes 2H, 1C y 2C e intercambiadoras E3, E5, y calentadores H1 y H2<\/li><li>Ciclo 3 (l\u00ednea azul), integrado por: corrientes 1H, 2H y 2C e intercambiadoras E1, E5, y calentadores C1 y C2<\/li><\/ul>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.11.41.png\" alt=\"\" class=\"wp-image-9012\" \/><noscript><img loading=\"lazy\" decoding=\"async\" width=\"954\" height=\"428\" src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.11.41.png\" alt=\"\" class=\"wp-image-9012\" srcset=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.11.41.png 954w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.11.41-300x135.png 300w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.11.41-768x345.png 768w\" sizes=\"auto, (max-width: 954px) 100vw, 954px\" \/><\/noscript><figcaption>Figura 6. <em>Diferentes tipos de ciclos. Algunos incluyen servicios.<\/em><\/figcaption><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Para afianzar tu entendimiento del tema, analiza el caso de la Figura 7 y revisa el video: <strong>Ciclos y rutas t\u00e9rmicas<\/strong> para estudiar c\u00f3mo se resuelve.&nbsp;&nbsp;<strong>&nbsp;<\/strong><\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.12.08.png\" alt=\"\" class=\"wp-image-9013\" \/><noscript><img loading=\"lazy\" decoding=\"async\" width=\"818\" height=\"525\" src=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.12.08.png\" alt=\"\" class=\"wp-image-9013\" srcset=\"https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.12.08.png 818w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.12.08-300x193.png 300w, https:\/\/blogs.ugto.mx\/rea\/wp-content\/uploads\/sites\/71\/2022\/02\/Captura-de-Pantalla-2022-03-10-a-las-14.12.08-768x493.png 768w\" sizes=\"auto, (max-width: 818px) 100vw, 818px\" \/><\/noscript><figcaption>Figura 7. <em>Caso de estudio.<\/em><\/figcaption><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\">Conclusi\u00f3n <\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">En conclusi\u00f3n, cuando se dise\u00f1a una red de recuperaci\u00f3n de calor utilizando el m\u00e9todo Pinch, es frecuente que el n\u00famero total de intercambiadores de calor final sea mayor al n\u00famero m\u00ednimo de equipos requeridos. La raz\u00f3n de esto tiene su origen en la naturaleza del m\u00e9todo de dise\u00f1o que separa al proceso en dos zonas que son independientes t\u00e9rmicamente. Al realizar el dise\u00f1o de la red de manera independiente y finalmente unirlas, el resultado puede ser que se generan ciclos. Un ciclo incrementa el n\u00famero de equipos de transferencia de calor y cuando el costo de cada unidad es alto, podr\u00eda resultar recomendable, desde el punto de vista del costo, reducir el n\u00famero de unidades.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En esta clase hemos analizado una metodolog\u00eda que se utiliza para romper ciclos a trav\u00e9s de la eliminaci\u00f3n de intercambiadores de calor. En la mayor\u00eda de los casos, la eliminaci\u00f3n de un equipo trae consigo un cambio en las temperaturas de la red como resultado del cambio en las cargas t\u00e9rmicas de los equipos.&nbsp;El resultado normalmente es que en algunos equipos la diferencia de temperatura se reduce por debajo del \u0394T<sub>min<\/sub> del proceso. Se puede estudiar la posibilidad de analizar c\u00f3mo ser\u00eda el efecto en el tama\u00f1o del intercambiador antes de pensar en restablecer la diferencia m\u00ednima de temperatura. Cuando el impacto es muy grande, se puede optar por restablecer el gradiente de temperatura a costa del incremento en el consumo de energ\u00eda. Para ello se hace uso de las rutas t\u00e9rmicas. Su principal caracter\u00edstica es que unen servicios auxiliares lo que les permite transferir carga t\u00e9rmica entre ellos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Las ideas principales de esta clase son:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>La existencia de ciclos en una red de intercambio de calor incrementa el n\u00famero de equipos.<\/li><li>Un ciclo permite transferir carga t\u00e9rmica entre intercambiadores de calor.<\/li><li>Un ciclo puede incluir servicios auxiliares del mismo tipo.<\/li><li>Una ruta t\u00e9rmica une servicios auxiliares de calentamiento y enfriamiento.<\/li><li>La ruta t\u00e9rmica es el medio para restablecer el gradiente de temperatura.<\/li><li>En esta metodolog\u00eda, el restablecimiento de la carga t\u00e9rmica se realiza basado en el balance de energ\u00eda de las corrientes.<\/li><li>Un an\u00e1lisis detallado implica la evaluaci\u00f3n de los requerimientos de \u00e1rea de los equipos afectados al variar las temperaturas internas de la red.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Has llegado al final de esta clase \u00a1Mis felicitaciones por tu gran logro! Para concluir la sesi\u00f3n te invito a realizar la tarea y mandarla como corresponde. Te encuentro en tu pr\u00f3xima clase, hasta entonces.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"fuentes-de-informacion\">Fuentes de informaci\u00f3n<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Video: Ciclos y rutas t\u00e9rmicas<\/li><li>Archivo PDF: Ciclos y rutas t\u00e9rmicas<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Introducci\u00f3n \u00a1Hola!&nbsp; Espero que este d\u00eda se complemente con muchas satisfacciones para ti y goces de una salud envidiable. Te doy una calurosa bienvenida a la d\u00e9cimo primera clase del curso Integraci\u00f3n de Procesos.&nbsp; El tema que abordaremos en esta sesi\u00f3n consiste en c\u00f3mo analizar, en la etapa de dise\u00f1o, las opciones para reducir el &#8230; <a title=\"Clase digital 11. Modificaciones a redes de recuperaci\u00f3n de calor para reducir del n\u00famero de equipos\" class=\"read-more\" href=\"https:\/\/blogs.ugto.mx\/rea\/clase-digital-11-modificaciones-a-redes-de-recuperacion-de-calor-para-reducir-del-numero-de-equipos\/\" aria-label=\"Leer m\u00e1s sobre Clase digital 11. Modificaciones a redes de recuperaci\u00f3n de calor para reducir del n\u00famero de equipos\">Leer m\u00e1s<\/a><\/p>\n","protected":false},"author":142,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_crdt_document":"","episode_type":"","audio_file":"","podmotor_file_id":"","podmotor_episode_id":"","cover_image":"","cover_image_id":"","duration":"","filesize":"","filesize_raw":"","date_recorded":"","explicit":"","block":"","itunes_episode_number":"","itunes_title":"","itunes_season_number":"","itunes_episode_type":"","footnotes":""},"categories":[247,248],"tags":[41,249,250],"class_list":["post-8143","post","type-post","status-publish","format-standard","hentry","category-maestria-en-ingenieria-quimica","category-uda-integracion-de-procesos","tag-clase-digital","tag-iima06033","tag-martin-picon-nunez"],"acf":[],"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/posts\/8143","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/users\/142"}],"replies":[{"embeddable":true,"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/comments?post=8143"}],"version-history":[{"count":2,"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/posts\/8143\/revisions"}],"predecessor-version":[{"id":9014,"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/posts\/8143\/revisions\/9014"}],"wp:attachment":[{"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/media?parent=8143"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/categories?post=8143"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blogs.ugto.mx\/rea\/wp-json\/wp\/v2\/tags?post=8143"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}